بررسی استوریج هیبرید NetApp FAS8000
Category : دستهبندی نشده
بررسی استوریج هیبرید NetApp FAS8000
Accelerate business operations and respond easily to changing requirements with unified, scalable hybrid storage.
Adapt faster to changing business needs and achieve core IT requirements for uptime, scalability and cost efficiency. The powerful NetApp® FAS8000 Series hybrid storage systems are built for business-critical workloads that demand high performance (up to 4M IOPS), multi-PB scale and leading flash integration.
Respond flexibly to changing business requirements. Build a foundation for a data fabric that enables you to maintain control of your data as you grow – on premises and in the cloud. Deliver performance across a broad range of SAN and NAS workloads.
Streamline IT operations. Leverage simplified management and proven cloud-provider integration to deploy the FAS8000 in your data centre or hybrid cloud. Non-disruptive operations simplify long-term scaling and improve uptime.
Deliver superior TCO. Increase utilisation and improve long-term ROI by way of proven storage efficiency and price/performance. Leverage your existing investments in third-party storage arrays using NetApp FlexArray™ storage virtualisation software to consolidate them behind the FAS8000.
Learn more about our FAS8000 series (PDF) enterprise storage systems.
Read how AFF all-flash arrays combine leading data management with sub-millisecond latency
Key Points
- Accelerate SAN and NAS workloads with flash; scale to 138PB.
- Build a flexible data fabric to manage your hybrid cloud environment.
- Perform installs 3x faster and simplify application integration.
- Consolidate storage and improve price/performance by 2x.
- Deliver non-disruptive operations and greater than 99.9999% availability.
Technical specifications for the NetApp FAS8000 Series hybrid storage arrays
See technical specifications that include the NetApp® FAS6290, FAS6250 and FAS6220.
See technical specifications that include the NetApp FAS3250 and FAS3220.
All data in this table applies to NetApp dual-controller hybrid and disk-only configurations. See the AFF all-flash array datasheet (PDF) for information about all-flash configurations.
FAS8080 EX | FAS8060 | FAS8040 | FAS8020 | |
---|---|---|---|---|
NAS Scaling | 1–24 nodes (12 HA pairs) | |||
Maximum Drives | 17,280 | 14,400 | 8,640 | 5,760 |
Maximum Capacity | 138PB | 115PB | 69PB | 46PB |
Maximum Flash Pool™ capacity | 1728TB | 864TB | 576TB | 288TB |
Maximum memory | 3072GB | 1536GB | 768GB | 576GB |
SAN Scaling | 1–8 nodes (4 HA pairs) | |||
Maximum Drives | 5,760 | 4,800 | 2,880 | 1,920 |
Maximum Capacity | 46PB | 38PB | 23PB | 15PB |
Maximum Flash Pool capacity | 576TB | 288TB | 192TB | 96TB |
Maximum memory | 1024GB | 512GB | 256GB | 192GB |
Cluster Interconnect | 2, 4, or 6 x 10GbE | 2 or 4 x 10GbE | 2 or 4 x 10GbE | 2 x 10GbE |
FAS8080 EX | FAS8060 | FAS8040 | FAS8020 | |
Maximum Capacity | 11520TB | 9600TB | 5,760TB | 3840TB |
Maximum Flash Pool capacity | 144TB | 72TB | 48TB | 24TB |
Maximum Drives | 1,440 | 1,200 | 720 | 480 |
Controller form factor | Dual enclosure HA; 2 controllers in two 6U chassis; total of 12U |
Dual-enclosure HA; 2 controllers and 2 IOXMs in two 6U chassis; total of 12U or Single-enclosure HA; 2 controllers in single 6U chassis |
Single-enclosure HA; 2 controllers in single 6U chassis | Single-enclosure HA; 2 controllers in single 3U chassis |
Memory | 256GB | 128GB | 64GB | 48GB |
Maximum Flash Cache™ | 24TB | 8TB | 4TB | 3TB |
Maximum Flash Pool | 144TB | 72TB | 48TB | 24TB |
Combined flash total | 144TB | 72TB | 48TB | 24TB |
NVRAM | 32GB | 16GB | 16GB | 8GB |
PCIe expansion slots | 24 | 8 or 24[1] | 8 | 4 |
Onboard I/O: UTA2 (10GbE/FCoE, 16Gb FC) |
8 | 8 | 8 | 4 |
Onboard I/O: 10GbE | 8 | 8 | 8 | 4 |
Onboard I/O: GbE | 8 | 8 | 8 | 4 |
Onboard I/O, 6Gb SAS | 8 | 8 | 8 | 4 |
Storage networking supported | FC, FCoE, iSCSI, NFS, pNFS, CIFS/SMB | |||
OS Version | ONTAP® 8.2.2 RC1 or higher | ONTAP 8.2.1 RC2 or higher | ||
High-availability Features | Alternate Control Path (ACP); Ethernet-based service processor and ONTAP management interface; redundant hot-swappable controllers, cooling fans, power supplies and optic. | |||
Supported configurations
ONTAP 9, 8.3 |
Hardware cluster configurations:
MetroCluster configurations for synchronous replication:
Consult the Interoperability Matrix Tool for FAS8000 support on earlier versions of ONTAP software. |
|||
Disk shelves supported | DS2246 (2U; 24 drives, 2.5” SFF) DS4246 (4U; 24 drives, 3.5” LFF) DS4486 (4U; 48 drives, 3.5” LFF) DS4243 (4U; 24 drives, 3.5″ LFF) supported for upgrades only DS14 disk shelves (mk2-AT, mk4) are supported for upgrades only See NetApp Disk Shelves and Storage Media for more details on each disk shelf and supported drive types. |
|||
Maximum RAID group sizes | RAID-TEC™ (triple parity, ONTAP 9)
RAID 6 (RAID-DP®)
RAID 4
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror®) |
|||
Operating systems supported | Windows® 2000, Windows Server® 2003, Windows Server 2008, Windows Server 2012, Windows XP, Linux®, Oracle® Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX® | |||
Max. Number of LUNs | FAS8020/FAS8040: 8,192 (ONTAP 9 and 8.3.x) FAS8060/FAS8080: 12,288 (ONTAP 9 and 8.3.x) 7-mode, all FAS8000 systems: 2048 |
|||
Number of supported SAN hosts | FAS8020/FAS8040: 4,096 (ONTAP 9 and 8.3.x) FAS8060/FAS8080: 8,192 (ONTAP 9 and 8.3.x) 7-mode, all FAS8000 systems: Up to 512 hosts per HA pair |
|||
FlexVol® volumes | (In hardware clusters) Up to 1,000 per controller; (7-mode) up to 500 per controller | |||
Snapshot® copies | Up to 255,000 per controller | |||
Maximum volume size | 100TB | 100TB | 100TB | 70TB |
Maximum aggregate size | 400TB | 400TB | 324TB | 324TB |
Maximum Port Count (Includes Integrated Ports and PCIe Expansion Slots) | ||||
FC target ports (16Gb autoranging) | 64 | 64 | 24 | 12 |
FC target ports (4Gb or 8Gb) | 64 | 64 | 40 | 20 |
FCoE target ports, UTA (max.) | 32 | 32 | 24 | 12 |
10GbE ports (max.) | 64 | 64 | 32 | 16 |
GbE ports (max.) | 72 | 72 | 40 | 20 |
6Gb/12Gb SAS ports (max.) | 56 | 56 | 40 | 20 |
FC initiator ports (max.) | 72 | 72 | 40 | 20 |
Maximum Adapters | ||||
Dual 10GbE (optical or copper) | 16 | 16 | 8 | 4 |
Dual 10Gbase-T (RJ-45, CAT 6A-E) | 16 | 16 | 8 | 4 |
Quad GbE (copper) | 16 | 16 | 8 | 4 |
Dual 10GbE/FCoE 16Gb FC Unified Target Adapter 2 (UTA2, optical or copper for 10GbE/FCoE deployments, optical for 16Gb FC) | 24 | 24 | 8 | 4 |
8Gb FC target | 16 | 16 | 8 | 4 |
Flash Cache Performance Acceleration Module (2TB) | 12 | 4 | 2 | 0 |
Flash Cache Performance Acceleration Module (1TB) | 24 | 8 | 4 | 2 |
Flash Cache Performance Acceleration Module (512GB) | 24 | 16 | 8 | 4 |
Quad 6Gb SAS storage HBA | 12 | 8 | 8 | 4 |
Quad 12Gb SAS storage HBA | 12 | 8 | 8 | 4 |
Quad 4Gb FC storage/tape HBA (fibre) | 16 | 8 | 8 | 4 |
FAS8080 EX | FAS8060 | FAS8040 | FAS8020 | |
---|---|---|---|---|
Thermal Rating (at 200V) | 2,880 BTU (typical, per enclosure)
3,252 BTU (worst case, per enclosure) |
2,031 BTU (typical)
2,362 BTU (worst case) |
1,495 BTU (typical)
1,843 BTU (worst case) |
1,205 BTU (typical)
1,450 BTU (worst case) |
Weight (heaviest) | 115.08lb. | 121.47lb. | 119.49lb. | 74.08lb. |
Height | 12U (6U per enclosure) | 6U or 12U[1] | 6U | 3U |
Width | 19″ IEC rack-compliant (17.6″, 44.7cm) | |||
Depth | 24.3” (28.9” w/cable management) | |||
Operating temperature, altitude and relative humidity | 10°C to 40°C (50°F to 104°F); at <= 3,000m (at <= 10,000′) elevation; 20% to 80% relative humidity, non-condensing (28°C wet bulb temperature) | |||
Non-operating temperature and relative humidity | –40°C to 70°C (–40°F to 158°F); 5% to 95% relative humidity, non-condensing, in original container | |||
Operating acoustic noise | FAS8020:
FAS8040/FAS8060:
FAS8080 EX:
|
|||
Compliance | RoHS-compliant (PDF) | |||
Safety/emissions/immunity | Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, CU, BIS, BSMI, SONCAP, NRCS LOA (South Africa)
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI |
FAS8080 EX | FAS8060 | FAS8040 | FAS8020 | |
---|---|---|---|---|
Rack space | 42U | |||
Dimensions (height/width/depth) | 78.75″ (200cm)/23.6″ (60cm)/44.3″ (112.5cm) | |||
Minimum cabinet clearances for airflow | 10″ (25.4cm) front and 12″ (30.5cm) rear | |||
Minimum cabinet clearances for service | 30″ (76.3cm) front and rear, 12″ top | |||
AC power | 200 to 240VAC | |||
Current | 30A single-phase or 3-phase | |||
Weight (empty) | 307lb. (138kg) | |||
Features | Split rear door with cable egress opening, reversible front door (left or right handed) |
[1] Requires ONTAP 8.2.3 or higher.
© 2016 NetApp, Inc. All rights reserved. No part of this document may be reproduced without the prior written consent of NetApp, Inc. Specifications are subject to change without notice. NetApp, the NetApp logo, ONTAP, Flash Cache, Flash Pool, FlexVol, MetroCluster, RAID DP, Snapshot and SyncMirror are trademarks or registered trademarks of NetApp, Inc. in the United States and/or other countries. Windows and Windows Server are registered trademarks of Microsoft Corporation. Linux is a registered trademark of Linus Torvalds. Oracle is a registered trademark of Oracle Corporation. VMware and ESX are registered trademarks of VMware, Inc. Mac is a registered trademark of Apple Inc. All other brands or products are trademarks or registered trademarks of their respective holders and should be treated as such.
FAS8000 systems feature the NetApp ONTAP software and advanced data management and data protection tools.
NetApp® FAS8000 software products deliver leading data management, storage efficiency and high performance. Optional extended-value software products provide advanced capabilities, including instant data recovery, instant cloning, data replication, disk-to-disk backup and application-aware backup and recovery.
NetApp FAS8000 Series | |||
---|---|---|---|
Features and Software Included with the ONTAP®Software |
Efficiency: FlexVol®, deduplication, compression, compaction[1] and thin provisioning
Availability: MetroCluster™ and Multipath I/O Data protection: RAID-TEC™[1], RAID-DP® and Snapshot® Performance: Storage QoS Management: OnCommand® Unified Manager, OnCommand Performance Manager, OnCommand Workflow Automation, OnCommand API Services, OnCommand System Manager |
||
Extended Value Software (optional) |
A Premium Bundle is available for purchase with FAS8000 systems that includes:
|
[1] Available with ONTAP 9